Technical Attributes

General Information
Brand ÖLFLEX®
Product type Railway cable
Copper index 672.000  kg/km
Copper index (lb) 4515.655  lb
Weight 771 kg/km
Electrical Characteristics
Nominal voltage U0/U: 1.8/3 kV AC rms according to IEC
Max. conductor resistance at 20°C 0.277  Ω/km
Test voltage 6.5  kV
Short-circuit temperature [5s] 200
Current rating according to EN 50355
Maximum operating voltage Um 3,6 kV AC
Product Design
Single core colour green/yellow
Conductor design IEC 60228 class 5: fine-wire
Nominal outer diameter 16.2  mm
Conductor material Tin-plated copper
Nominal conductor cross-section (metric) 70  mm²
Cable dimensions 1G70
Shielded

Cable shape Round
Insulation colour natural
Cable design abbreviations for railway vehicles Type OM
Number of cores 1
Core insulation basic material Electron beam cross-linked polymer compound
Single core identification Strips, two-coloured
Including protective earth

Basic material covering Electron beam cross-linked polymer compound
Product Characteristics
Flame-retardant

Temperature, occasionally moved min -35
Temperature, fixed installation min -40
Temperature, fixed installation max 125
Ozone-resistant

UV-resistant

Minimum bending radius in mm, fixed installation 64.8  mm
Fuel-resistant

Application area Fixed installation
max. conductor temperature, occasionally moved -35 °C to 90 °C max. conductor temperature
Low smoke density according to IEC 61034-2, ANSI/UL1685, BS 6853 appendix D
Oil-resistant

Low toxicity of combustion gases according to EN 50305
Minimum bending radius in mm, occasionally flexing 81.0  mm
Minimum bending radius, stationary 4 x outer diameter
Minimum bending radius, occasionally flexing 5 x outer diameter
Temperature, fixed installation -40 °C to 125 °C max. conductor temperature
Flame retardance according to IEC 60332-1-2, EN 50305, BS 6853, UL FT4
Halogen-free

Temperature, occasionally moved max 90
Certifications and Standards
Fire protection for railway vehicles hazard level EN 45545-2 HL1, EN 45545-2 HL2, EN 45545-2 HL3, BS 6853 Interior use Ia, Ib, II, BS 6853 Exterior use Ia, Ib, II
Fire protection tested for railway vehicles

CE marking

VDE certified

Documentation
Notes
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
Product Family List
All articles from ÖLFLEX® TRAIN 4GKW
Article number Number of cores Including protective conductor Conductor cross-section (mm2) Single core colour Imp outer dia cable sheath nom Nominal outer diameter Copper index calc export Weight
85165003 1 No 4 black 4.5 50 kg/km
85165008 1 No 35 black 11.9 401 kg/km
85165009 1 No 50 black 14.3 572 kg/km
85165010 1 No 70 black 16.2 771 kg/km
85165011 1 No 95 black 18.1 1011 kg/km
85165014 1 No 185 black 24.6 1908 kg/km
85165016 1 No 300 black 30.6 3066 kg/km
85165021 1 Yes 2.5 green/yellow 4.0 35 kg/km
85165022 1 Yes 4 green/yellow 4.5 50 kg/km
85165023 1 Yes 6 green/yellow 5.3 71 kg/km
85165024 1 Yes 10 green/yellow 6.5 117 kg/km
85165025 1 Yes 16 green/yellow 8.6 193 kg/km
85165026 1 Yes 25 green/yellow 10.3 290 kg/km
85165027 1 Yes 35 green/yellow 11.9 401 kg/km
85165028 1 Yes 50 green/yellow 14.3 572 kg/km
85165029 1 Yes 70 green/yellow 16.2 771 kg/km
85165030 1 Yes 95 green/yellow 18.1 1011 kg/km