Technical Attributes

General Information
Brand ETHERLINE®
Product type Ethernet cable
valid fieldbus or Ethernet system ETHERNET/IP, PROFINET
Copper index 38.000  kg/km
Copper index (lb) 255.300  lb
Weight 77 kg/km
Electrical Characteristics
Maximum operating voltage (not for power transmission) 125
Nominal surge impedance 100
Nominal voltage 48 V AC rms according to IEC
Supports Power over Ethernet IEEE 802.3af (PoE), IEEE 802.3at (PoE+), IEEE 802.3bt (4PPoE)
Loop resistance at 20°C 173.0
Possible data transmission rates 10000
Signal propagation speed (nom.) 0.74
Test voltage core/screening 1
Test voltage core/core 1
Product Design
Min. core diameter 1.2
Nominal core diameter 1.3
Conductor design 7-wire
Nominal outer diameter 8.1  mm
Max. core diameter 1.4
Conductor material Tin-plated copper
Min. outer diameter 7.5
Nominal conductor cross-section (metric) 0.22  mm²
Conductor number/size 24/7
Optical degree of coverage of the stranded screening, overall screen 85
Shielded

Core identification Colours
Cable shape Round
Number of pairs 4
Outer sheath colour blue
Stranding type Twisted-pair
Pair shielding type Aluminium-laminated plastic foil
Leading conductor cross-section AWG
Shielding, short form S/FTP
With rodent protection

Type of overall screening Tin-plated copper braiding
Number of cores 8
Nominal conductor cross-section (AWG) 24 AWG
Core insulation basic material Polyethylene foam
Basic material of outer sheath Polyurethane
Including protective earth

Core insulation basic material, short form Foam-Skin PE
With armouring

Max. outer diameter 8.2
Cable sheath RAL colour RAL 5021
Number of wires 7
Basic material of outer sheath, short form PUR
Product Characteristics
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Halogen-free according to VDE 0472-815
For permanent bending

Temperature, occasionally moved min -30
Acid-resistant

Fast Connect (FC) cable

PROFINET® application Type C
Temperature, fixed installation min -40
Temperature, fixed installation max 105
Chemical resistant

Installation temperature min. -30
UV-resistant

Minimum bending radius in mm, fixed installation 82.0  mm
PWIS-free

Application area Flexible
max. conductor temperature, occasionally moved -30 °C to 105 °C max. conductor temperature
Oil-resistant

Ethernet cable category Cat.7
Minimum bending radius in mm, occasionally flexing 123.0  mm
Max. assembly temperature 105
Minimum bending radius, stationary 10 x outer diameter
Minimum bending radius, occasionally flexing 15 x outer diameter
Temperature, fixed installation -40 °C to 105 °C max. conductor temperature
Flame retardance according to ISO 6722-1 5.22
Windable

For torsional load

Halogen-free

Temperature, occasionally moved max 105
Certifications and Standards
cUR recognised

CSA certified

Fire protection tested for railway vehicles

Ecolab certified

cUL listed

Flame retardance tested according to UN/ECE-R118

UL listed

CE marking

UL recognized

VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
EAC-certified

Documentation
Notes
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • PROFINET® is a registered trademark of PNO (PROFIBUS user organisation).
Product Family List
All articles from ETHERLINE® HEAT 6722
Article number Conductor number/size Ethernet cable category Imp outer dia cable sheath nom Nominal outer diameter Copper index calc export Weight
2170581 4X2X24/7AWG Cat.6A 8.1 77 kg/km
2170582 24/7 Cat.7 8.1 77 kg/km
2170850 24/7 Cat.5e 7.7 72 kg/km