Technical Attributes

General Information
Brand ETHERLINE®
Product type Ethernet cable
valid fieldbus or Ethernet system ETHERNET/IP, EtherCAT, Ethernet, CC-Link IE
Copper index 27.000  kg/km
Copper index (lb) 181.400  lb
Weight 56 kg/km
Country of Origin
Italy. Note: The country of origin may vary depending on the actual goods supplied. Please contact us to confirm the country of origin for your order.
Electrical Characteristics
Maximum operating voltage (not for power transmission) 125
Nominal surge impedance 100
Segregation class according to EN 50174-2 C
Nominal voltage 48 V AC rms according to IEC
Supports Power over Ethernet IEEE 802.3af (PoE), IEEE 802.3at (PoE+), IEEE 802.3bt (4PPoE)
Loop resistance at 20°C 290
Possible data transmission rates 1000
Signal propagation speed (nom.) 0.67
Test voltage core/screening 3
Test voltage core/core 3
Rated voltage core to core 50 V AC rms according to IEC
Product Design
Conductor design 19-wire
Nominal outer diameter 6.3  mm
Max. core diameter 1.08
Conductor material Bare copper
Min. outer diameter 6
Conductor number/size 4x2x26/19AWG
Optical degree of coverage of the stranded screening, overall screen 85
Shielded

Core identification Colours
Cable shape Round
Number of pairs 4
base material inner sheath shortname TPE
Outer sheath colour water blue
Stranding type Twisted-pair
Leading conductor cross-section AWG
Shielding, short form S/UTP
Type of overall screening Tin-plated copper braiding
Number of cores 8
Nominal conductor cross-section (AWG) 26 AWG
Core insulation basic material Polyolefin
Basic material of outer sheath Polyurethane
Basic material of inner sheath Thermoplastic elastomers
Including protective earth

Core insulation basic material, short form PO
Max. outer diameter 6.6
Cable sheath RAL colour RAL 5021
Number of wires 19
Basic material of outer sheath, short form PUR
Product Characteristics
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Halogen-free according to VDE 0472-815
For permanent bending

Temperature, occasionally moved min -5
Fast Connect (FC) cable

Temperature, fixed installation min -30
Minimum bending radius in mm, dynamic continuously flexing 99.0  mm
Temperature, fixed installation max 80
Installation temperature min. -5
UV-resistant

Minimum bending radius in mm, fixed installation 52.8  mm
PWIS-free

Application area Cable chain, Flexible
max. conductor temperature, occasionally moved -5 °C to 70 °C max. conductor temperature
Oil-resistant

Ethernet cable category Cat.5e
Minimum bending radius in mm, occasionally flexing 99.0  mm
Max. assembly temperature 70
Minimum bending radius, stationary 8 x outer diameter
Minimum bending radius, occasionally flexing 15 x outer diameter
Temperature, fixed installation -30 °C to 80 °C max. conductor temperature
Flame retardance according to UL FT2
Oil resistance according to DIN EN 60811-2-1
Minimum bending radius, dynamic continuously flexing 15 x outer diameter
Windable

For torsional load

Halogen-free

Temperature, occasionally moved max 70
Certifications and Standards
cUR recognised

CSA certified

UL AWM certification 21576 according to UL 758 (e-file number: E63634)
cUL listed

UL listed

cUR certification AWM I A according to CSA C22.2 No. 210 (e-file number: E63634), AWM II B according to CSA C22.2 No. 210 (e-file number: E63634), AWM II A according to CSA C22.2 No. 210 (e-file number: E63634), AWM I B according to CSA C22.2 No. 210 (e-file number: E63634)
CE marking

UL recognized

VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
EAC-certified

Documentation
Product Family List
All articles from ETHERLINE® Cat.5e FD
Article number Conductor number/size Number of cores Imp outer dia cable sheath nom Nominal outer diameter Weight Copper index calc export
2170289 2x2x26/19AWG 4 5.9 48 kg/km
2170489 4x2x26/19AWG 8 6.3 56 kg/km