General Information
Product type Installation cable
Copper index 21.000  kg/km
Copper index (lb) 141.100  lb
Weight 60 kg/km
Country of Origin
To be confirmed based on the actual goods supplied. Please contact us for confirmation before placing your order.
Electrical Characteristics
Loop resistance at 20°C 73.2
Max. conductor resistance at 20°C 36  Ω/km
Test voltage core/screening 0.8
Test voltage core/core 0.8
Product Design
Nominal outer diameter 7  mm
Conductor material Bare copper
Cable dimensions 2X2X0.8
Shielded

Nominal conductor diameter (mm) 0.8
J-indoor telecommunication cable J-Y(ST)Y…LG
Core identification Colours
Cable shape Round
Number of pairs 2
Outer sheath colour red
Stranding type Star quad
Conductor colour code VDE 0815
Type of overall screening Aluminium-laminated plastic foil
Core insulation basic material Polyvinylchloride
Basic material of outer sheath Polyvinylchloride
Including protective earth

Core insulation basic material, short form PVC
Cable sheath RAL colour RAL 3000
Basic material of outer sheath, short form PVC
Product Characteristics
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Temperature, occasionally moved min -5
Temperature, fixed installation min -30
Temperature, fixed installation max 70
UV-resistant

Minimum bending radius in mm, fixed installation 70.0  mm
PWIS-free

Application area Flexible, Fixed installation
max. conductor temperature, occasionally moved -5 °C to 50 °C max. conductor temperature
Oil-resistant

Minimum bending radius, stationary 10 x outer diameter
Water-resistant

Temperature, fixed installation -30 °C to 70 °C max. conductor temperature
Flame retardance according to IEC 60332-1-2
Halogen-free

Temperature, occasionally moved max 50
Certifications and Standards
Flame retardance tested according to UN/ECE-R118

CE marking

CPR fire class Eca
VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20, ЕАЭС N RU Д-DE.РА01.В.47116/21
EAC-certified

Documentation
Notes
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Trade product, not a LAPP product.
Product Family List
All articles from J-Y(ST)Y...LG Fire Alarm Cable
Article number Number of pairs Imp diam cond in nom Nominal conductor diameter (mm) Imp outer dia cable sheath nom Nominal outer diameter Copper index calc export Weight
1708001 1 0.8 6 26 kg/km
1708002 2 0.8 7 60 kg/km
1708004 4 0.8 9 100 kg/km
1708010 10 0.8 13.5 220 kg/km