Technical Attributes

General Information
Brand ÖLFLEX®
Product type Power and control cable
Copper index 72.000  kg/km
Copper index (lb) 483.800  lb
Weight 145 kg/km
Electrical Characteristics
Nominal voltage U0/U: 450/750 V AC rms according to IEC
Max. conductor resistance at 20°C 8.21  Ω/km
Inductance (800 Hz), approx. 0.712
Test voltage 4  kV
Fixed installation nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Conductor/conductor operating capacitance (800Hz), approx. 52
Product Design
Conductor design IEC 60228 class 5: fine-wire
Nominal outer diameter 9.7  mm
Conductor material Tin-plated copper
Nominal conductor cross-section (metric) 2.5  mm²
Cable dimensions 3G2.5
Shielded

Core identification Colours
Cable shape Round
Outer sheath colour black
Stranding type Layered stranding
Number of cores 3
Core insulation basic material Electron beam cross-linked polymer compound
Basic material of outer sheath Electron beam cross-linked polymer compound
Including protective earth

Cable sheath RAL colour RAL 9005
Product Characteristics
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Halogen-free according to IEC 60754-1
Temperature, occasionally moved min -35
Temperature, fixed installation min -55
Temperature, fixed installation max 125
UV-resistant

Minimum bending radius in mm, fixed installation 38.8  mm
PWIS-free

Application area Flexible, Fixed installation
max. conductor temperature, occasionally moved -35 °C to 120 °C max. conductor temperature
Oil-resistant

Minimum bending radius in mm, occasionally flexing 145.5  mm
Minimum bending radius, stationary 4 x outer diameter
Minimum bending radius, occasionally flexing 15 x outer diameter
Temperature, fixed installation -55 °C to 125 °C max. conductor temperature
Flame retardance according to IEC 60332-3-22, IEC 60332-3-24, IEC 60332-3-25, NF-C 32-070 (C1), NF-F 16-101 (C)
Oil resistance according to IEC 60227-1 (ST9), EN 50264-1 EM104
UV-resistant according to EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use), DIN EN ISO 4892-2 method A
Max. short-term temperature 145
Halogen-free

Temperature, occasionally moved max 120
Certifications and Standards
DNV-certified

CPR drip behaviour d1
CPR smoke density s1a
Flame retardance tested according to UN/ECE-R118

CPR acidity a1
CE marking

CPR fire class B2ca
VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
EAC-certified

Documentation
Product Family List
All articles from ÖLFLEX® HEAT 125 MC 450/750 V
Article number Number of cores Including protective conductor Conductor cross-section (mm2) Nominal voltage Imp outer dia cable sheath nom Nominal outer diameter Copper index calc export Weight
1024323 2 No 1.5 U0/U: 450/750 V AC rms according to IEC 7.6 71 kg/km
1024324 3 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 8.3 96 kg/km
1024325 4 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 9 123 kg/km
1024326 5 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 10.1 156 kg/km
1024327 7 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 11.2 224 kg/km
1024328 12 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 15.1 316 kg/km
1024333 2 No 2.5 U0/U: 450/750 V AC rms according to IEC 9 102 kg/km
1024334 3 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 9.7 145 kg/km
1024335 4 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 10.8 189 kg/km
1024336 5 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 11.9 235 kg/km
1024337 7 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 13.2 344 kg/km
1024341 4 Yes 4 U0/U: 450/750 V AC rms according to IEC 12.7 276 kg/km
1024342 5 Yes 4 U0/U: 450/750 V AC rms according to IEC 14 334 kg/km
1024346 4 Yes 6 U0/U: 450/750 V AC rms according to IEC 14.1 341 kg/km
1024347 5 Yes 6 U0/U: 450/750 V AC rms according to IEC 15.8 431 kg/km